Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Viruses ; 15(1)2022 Dec 28.
Article in English | MEDLINE | ID: covidwho-2236069

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the aetiological agent of coronavirus disease 2019 (COVID-19) that has caused a pandemic with millions of human infections. There continues to be a pressing need to develop potential therapies and vaccines to inhibit SARS-CoV-2 infection to mitigate the ongoing pandemic. Epidemiological data from the current pandemic indicates that there may be sex-dependent differences in disease outcomes. To investigate these differences, we proposed to use common small animal species that are frequently used to model disease with viruses. However, common laboratory strains of mice are not readily infected by SARS-CoV-2 because of differences in the angiotensin-converting enzyme 2 (ACE2), the cellular receptor for the virus. To overcome this limitation, we transduced common laboratory accessible strains of mice of different sexes and age groups with a novel a triple AAV6 mutant, termed AAV6.2FF, encoding either human ACE2 or luciferase via intranasal administration to promote expression in the lung and nasal turbinates. Infection of AAV-hACE2-transduced mice with SARS-CoV-2 resulted in high viral titers in the lungs and nasal turbinates, establishment of an IgM and IgG antibody response, and modulation of lung and nasal turbinate cytokine profiles. There were insignificant differences in infection characteristics between age groups and sex-related differences; however, there were significant strain-related differences between BALB/c vs. C57BL/6 mice. We show that AAV-hACE2-transduced mice are a useful for determining immune responses and for potential evaluation of SARS-CoV-2 vaccines and antiviral therapies, and this study serves as a model for the utility of this approach to rapidly develop small-animal models for emerging viruses.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Humans , Mice , Angiotensin-Converting Enzyme 2/genetics , COVID-19/prevention & control , COVID-19 Vaccines , Dependovirus/genetics , Dependovirus/metabolism , Disease Models, Animal , Mice, Inbred C57BL , SARS-CoV-2/genetics , SARS-CoV-2/metabolism
2.
iScience ; 24(11): 103219, 2021 Nov 19.
Article in English | MEDLINE | ID: covidwho-1587475

ABSTRACT

The pandemic severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the cause of coronavirus disease 2019 (COVID-19). Worldwide efforts are being made to develop vaccines to mitigate this pandemic. We engineered two recombinant Newcastle disease virus (NDV) vectors expressing either the full-length SARS-CoV-2 spike protein (NDV-FLS) or a version with a 19 amino acid deletion at the carboxy terminus (NDV-Δ19S). Hamsters receiving two doses (prime-boost) of NDV-FLS developed a robust SARS-CoV-2-neutralizing antibody response, with elimination of infectious virus in the lungs and minimal lung pathology at five days post-challenge. Single-dose vaccination with NDV-FLS significantly reduced SARS-CoV-2 replication in the lungs but only mildly decreased lung inflammation. NDV-Δ19S-treated hamsters had a moderate decrease in SARS-CoV-2 titers in lungs and presented with severe microscopic lesions, suggesting that truncation of the spike protein was a less effective strategy. In summary, NDV-vectored vaccines represent a viable option for protection against COVID-19.

3.
iScience ; 24(12): 103530, 2021 Dec 17.
Article in English | MEDLINE | ID: covidwho-1536618

ABSTRACT

The golden hamster model of SARS-CoV-2 infection recapitulates key characteristics of COVID-19. In this work we examined the influence of the route of exposure, sex, and age on SARS-CoV-2 pathogenesis in hamsters. We report that delivery of SARS-CoV-2 by a low- versus high-volume intranasal or intragastric route results in comparable viral titers in the lung and viral shedding. However, low-volume intranasal exposure results in milder weight loss, whereas intragastric exposure leads to a diminished capacity to regain body weight. Male hamsters, and particularly older male hamsters, display an impaired capacity to recover from illness and delayed viral clearance. These factors were found to influence the nature of the host inflammatory cytokine response but had a minimal effect on the quality and durability of the humoral immune response and susceptibility to re-infection. These data further elucidate key factors that impact pre-clinical challenge studies carried out in the hamster model of COVID-19.

4.
iScience ; 2021.
Article in English | EuropePMC | ID: covidwho-1451806

ABSTRACT

The pandemic severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the cause of Coronavirus Disease 2019 (COVID-19). Worldwide efforts are being made to develop vaccines to mitigate this pandemic. We engineered two recombinant Newcastle disease virus (NDV) vectors expressing either the full-length SARS-CoV-2 spike protein (NDV-FLS) or a version with a 19 amino acid deletion at the carboxy terminus (NDV-Δ19S). Hamsters receiving two doses (prime-boost) of NDV-FLS developed a robust SARS-CoV-2-neutralizing antibody response, with elimination of infectious virus in the lungs and minimal lung pathology at five days post-challenge. Single-dose vaccination with NDV-FLS significantly reduced SARS-CoV-2 replication in the lungs, but only mildly decreased lung inflammation. NDV-Δ19S-treated hamsters had a moderate decrease in SARS-CoV-2 titers in lungs and presented with severe microscopic lesions, suggesting that truncation of the spike protein was a less effective strategy. In summary, NDV-vectored vaccines represent a viable option for protection against COVID-19. Graphical Abstract

5.
Sci Rep ; 11(1): 18316, 2021 09 15.
Article in English | MEDLINE | ID: covidwho-1412847

ABSTRACT

Shortages of personal protective equipment for use during the SARS-CoV-2 pandemic continue to be an issue among health-care workers globally. Extended and repeated use of N95 filtering facepiece respirators without adequate decontamination is of particular concern. Although several methods to decontaminate and re-use these masks have been proposed, logistic or practical issues limit adoption of these techniques. In this study, we propose and validate the use of the application of moist heat (70 °C with humidity augmented by an open pan of water) applied by commonly available hospital (blanket) warming cabinets to decontaminate N95 masks. This report shows that a variety of N95 masks can be repeatedly decontaminated of SARS-CoV-2 over 6 h moist heat exposure without compromise of their filtering function as assessed by standard fit and sodium chloride aerosol filtration efficiency testing. This approached can easily adapted to provide point-of-care N95 mask decontamination allowing for increased practical utility of mask recycling in the health care setting.


Subject(s)
Decontamination/methods , N95 Respirators/virology , SARS-CoV-2/physiology , Equipment Reuse , Hospitals , Humans , Humidity , Point-of-Care Systems , Time Factors , Virus Inactivation
6.
Nat Commun ; 12(1): 3612, 2021 06 14.
Article in English | MEDLINE | ID: covidwho-1267996

ABSTRACT

Widespread circulation of SARS-CoV-2 in humans raises the theoretical risk of reverse zoonosis events with wildlife, reintroductions of SARS-CoV-2 into permissive nondomesticated animals. Here we report that North American deer mice (Peromyscus maniculatus) are susceptible to SARS-CoV-2 infection following intranasal exposure to a human isolate, resulting in viral replication in the upper and lower respiratory tract with little or no signs of disease. Further, shed infectious virus is detectable in nasal washes, oropharyngeal and rectal swabs, and viral RNA is detectable in feces and occasionally urine. We further show that deer mice are capable of transmitting SARS-CoV-2 to naïve deer mice through direct contact. The extent to which these observations may translate to wild deer mouse populations remains unclear, and the risk of reverse zoonosis and/or the potential for the establishment of Peromyscus rodents as a North American reservoir for SARS-CoV-2 remains unknown.


Subject(s)
COVID-19/veterinary , Peromyscus/virology , Zoonoses/transmission , Animals , Animals, Wild , Antibodies, Neutralizing/immunology , COVID-19/pathology , COVID-19/transmission , Disease Susceptibility , Feces/virology , Female , Histiocytes/pathology , Humans , Male , Neutrophils/immunology , Neutrophils/pathology , RNA, Viral/isolation & purification , SARS-CoV-2/classification , SARS-CoV-2/genetics , United States , Zoonoses/virology
7.
PLoS One ; 16(6): e0253068, 2021.
Article in English | MEDLINE | ID: covidwho-1264227

ABSTRACT

The novel coronavirus, SARS-CoV-2, has spread into a pandemic since its emergence in Wuhan, China in December of 2019. This has been facilitated by its high transmissibility within the human population and its ability to remain viable on inanimate surfaces for an extended period. To address the latter, we examined the effect of simulated sunlight on the viability of SARS-CoV-2 spiked into tissue culture medium or mucus. The study revealed that inactivation took 37 minutes in medium and 107 minutes in mucus. These times-to-inactivation were unexpected since they are longer than have been observed in other studies. From this work, we demonstrate that sunlight represents an effective decontamination method but the speed of decontamination is variable based on the underlying matrix. This information has an important impact on the development of infection prevention and control protocols to reduce the spread of this deadly pathogen.


Subject(s)
COVID-19/virology , Decontamination/methods , Mucus/virology , SARS-CoV-2/radiation effects , Sunlight , Virus Inactivation/radiation effects , Humans , Microbial Viability/radiation effects , SARS-CoV-2/physiology
8.
Sci Rep ; 11(1): 984, 2021 01 13.
Article in English | MEDLINE | ID: covidwho-1065930

ABSTRACT

The spread of COVID-19 in healthcare settings is concerning, with healthcare workers representing a disproportionately high percentage of confirmed cases. Although SARS-CoV-2 virus has been found to persist on surfaces for a number of days, the extent and duration of fomites as a mode of transmission, particularly in healthcare settings, has not been fully characterized. To shed light on this critical matter, the present study provides the first comprehensive assessment of SARS-CoV-2 stability on experimentally contaminated personal protective equipment (PPE) widely used by healthcare workers and the general public. Persistence of viable virus was monitored over 21 days on eight different materials, including nitrile medical examination gloves, reinforced chemical resistant gloves, N-95 and N-100 particulate respirator masks, Tyvek, plastic, cotton, and stainless steel. Unlike previous reports, viable SARS-CoV-2 in the presence of a soil load persisted for up to 21 days on experimentally inoculated PPE, including materials from filtering facepiece respirators (N-95 and N-100 masks) and a plastic visor. Conversely, when applied to 100% cotton fabric, the virus underwent rapid degradation and became undetectable by TCID50 assay within 24 h. These findings underline the importance of appropriate handling of contaminated PPE during and following use in high-risk settings and provide interesting insight into the potential utility of cotton in limiting COVID-19 transmission.


Subject(s)
Personal Protective Equipment , SARS-CoV-2/physiology , Porosity , RNA, Viral/genetics , SARS-CoV-2/genetics , Surface Properties
9.
PLoS One ; 15(12): e0243965, 2020.
Article in English | MEDLINE | ID: covidwho-978945

ABSTRACT

The response to the COVID-19 epidemic is generating severe shortages of personal protective equipment around the world. In particular, the supply of N95 respirator masks has become severely depleted, with supplies having to be rationed and health care workers having to use masks for prolonged periods in many countries. We sought to test the ability of 7 different decontamination methods: autoclave treatment, ethylene oxide gassing (ETO), low temperature hydrogen peroxide gas plasma (LT-HPGP) treatment, vaporous hydrogen peroxide (VHP) exposure, peracetic acid dry fogging (PAF), ultraviolet C irradiation (UVCI) and moist heat (MH) treatment to decontaminate a variety of different N95 masks following experimental contamination with SARS-CoV-2 or vesicular stomatitis virus as a surrogate. In addition, we sought to determine whether masks would tolerate repeated cycles of decontamination while maintaining structural and functional integrity. All methods except for UVCI were effective in total elimination of viable virus from treated masks. We found that all respirator masks tolerated at least one cycle of all treatment modalities without structural or functional deterioration as assessed by fit testing; filtration efficiency testing results were mostly similar except that a single cycle of LT-HPGP was associated with failures in 3 of 6 masks assessed. VHP, PAF, UVCI, and MH were associated with preserved mask integrity to a minimum of 10 cycles by both fit and filtration testing. A similar result was shown with ethylene oxide gassing to the maximum 3 cycles tested. Pleated, layered non-woven fabric N95 masks retained integrity in fit testing for at least 10 cycles of autoclaving but the molded N95 masks failed after 1 cycle; filtration testing however was intact to 5 cycles for all masks. The successful application of autoclaving for layered, pleated masks may be of particular use to institutions globally due to the virtually universal accessibility of autoclaves in health care settings. Given the ability to modify widely available heating cabinets on hospital wards in well-resourced settings, the application of moist heat may allow local processing of N95 masks.


Subject(s)
Decontamination/methods , Equipment Reuse , N95 Respirators/virology , COVID-19/pathology , COVID-19/virology , Ethylene Oxide/pharmacology , Humans , Hydrogen Peroxide/pharmacology , Peracetic Acid/pharmacology , Plasma Gases/pharmacology , SARS-CoV-2/drug effects , SARS-CoV-2/isolation & purification , SARS-CoV-2/radiation effects , Ultraviolet Rays , Vesiculovirus/drug effects , Vesiculovirus/radiation effects
10.
J Virol Methods ; 285: 113947, 2020 11.
Article in English | MEDLINE | ID: covidwho-695693

ABSTRACT

On March 11, 2020, the World Health Organization (WHO) assessed COVID-19, caused by SARS-CoV-2, as a pandemic. As of June 1, 2020, SARS-CoV-2 has had a documented effect of over 6 million cases world-wide, amounting to over 370,000 deaths (World Health Organization, 2020. Novel Coronavirus (COVID-19) Situation. http://https://covid19.who.int/). Consequently, the high demand for testing has resulted in a depletion of commercially available consumables, including the recommended swabs and viral transport media (VTM) required for nasopharyngeal sampling. Therefore, the potential use of unvalidated alternatives must be explored to address the global shortage of testing supplies. To tackle this issue, we evaluated the utility of different swabs and transport mediums for the molecular detection of SARS-CoV-2. This study compared the performance of six swabs commonly found in primary and tertiary health care settings (PurFlock Ultra, FLOQSwab, Puritan Pur-Wraps cotton tipped applicators, Puritan polyester tipped applicators, MedPro 6" cotton tipped applicators, and HOLOGIC Aptima) for their efficacy in testing for SARS-CoV-2. Separately, the molecular detection of SARS-CoV-2 was completed from different transport mediums (DMEM, PBS, 100 % ethanol, 0.9 % normal saline and VTM), which were kept up to three days at room temperature (RT). The results indicate that there is no meaningful difference in viral yield from different swabs and most transport mediums for the collection and detection of SARS-CoV-2, indicating swab and medium alternatives could be used if supplies run out.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Coronavirus Infections/virology , Pneumonia, Viral/diagnosis , Pneumonia, Viral/virology , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques/methods , Clinical Laboratory Techniques/standards , Coronavirus Infections/epidemiology , Humans , Pandemics , Pneumonia, Viral/epidemiology , Reproducibility of Results , SARS-CoV-2 , Specimen Handling/methods , Specimen Handling/standards
11.
Appl Biosaf ; 25(3): 157-160, 2020 Sep 01.
Article in English | MEDLINE | ID: covidwho-634266

ABSTRACT

Introduction: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is classified as a Risk Group 3 pathogen; propagative work with this live virus should be conducted in biosafety level-3 (BSL-3) laboratories. However, inactivated virus can be safely handled in BSL-2 laboratories. Gamma irradiation is one of the methods used to inactivate a variety of pathogens including viruses. Objective: To determine the radiation dose required to inactivate SARS-CoV-2 and its effect, if any, on subsequent polymerase chain reaction (PCR) assay. Methods: Aliquots of SARS-CoV-2 virus culture were subjected to increasing doses of gamma radiation to determine the proper dose required to inactivate the virus. Real-time quantitative polymerase chain reaction (RT-qPCR) data from irradiated samples was compared with that of the non-irradiated samples to assess the effect of gamma radiation on PCR assay. Results: A radiation dose of 1 Mrad was required to completely inactivate 106.5 TCID50/ml of SARS-CoV-2. The influence of gamma radiation on PCR sensitivity was inversely related and dose-dependent up to 0.5 Mrad with no further reduction thereafter. Conclusion: Gamma irradiation can be used as a reliable method to inactivate SARS-CoV-2 with minimal effect on subsequent PCR assay.

SELECTION OF CITATIONS
SEARCH DETAIL